MACHINE SPECIFICATIONS AND STANDARD FEATURES:
- Heat Sealing Area - 15 in. X 18 in. (38.1 cm x 45.7cm)
- Manually operated dual aluminum shuttles, clear anodized, on smooth 1” diameter stainless shafts w/non-lube linear ball bearings
- Two hand safety start sensors (not buttons), ergonomically correct Banner Opti-touch
- Emergency stops (2), includes stationary safety shields
- Heating Elements - 240v or 480v, Large mass flat 1” heat plate w/internal heaters
- Seal Platen – precision machined Aluminum, Dupont Teflon Silverstone coating is included
- Electrical Requirements - 3 KW on 220 V., 220/240v or 480v; 1ph or 3ph available
- Sealing Pressure – adjustable up to 5,000 pounds, precision stationary surface plate supports tool shuttle
- Floor Space – 68” X 35” (172 cm x 89cm) resulting in no wasted space compared to carrousels
- Machine mounted non-mar casters w/height adjustment
- Rigid welded 3/16” steel tubular framework w/powder coat paint White standard or optional Steel-it gray (specify on ordering)
- Quick change lift off tooling receivers to provide versatility and productivity; includes SS locator pins for tooling plates
- Weight - 450 pounds (204kg); rugged, durable, not made of angle and sheet metal
- Programmable Time and Temperature controls w/limits is standard
- Electronic process monitoring with temperature & air pressure sensor fail-safe alarms for parameter settings, PW protected.
- Alarm screen details and alarm warning lights.
- Pressure regulation w/precision manual adjustment & liquid filled precision gauge
- Pressure validation port for easy calibration gage connection to pressure circuit
- Timer and individual thermocouple calibration connection ports
- Air Dump Safety valve, OSHA approved.
- Eye level controls including PLC screen, reset(s) and others.
- Four (4) thermocouples for control feedback & accurate individual temperature displays
- Infrared Thermal Vision System (patented) sensors (4) to sense platen surface temp, calibrated at 240 degrees F nominal set point. PLC IR sensor readings individually displayed on screen, for ref only.
- English or Metric units of measure readouts (specify at ordering)
- Password protection capable
- Air Usage - .35 CFM @ 80 PSI at 4 cycles per minute. Supply @ 100psi with 3/4”+ dia line minimum.
- Single exhaust port connection to discharge line from room or w/ standard muffler system provided
Owner’s manual, schematics and Atlas Vac programs on CD ROM. Sealer is ready for operation upon connection to air and electric power; air filter and gauge included.
Precision machined tooling nests are quoted separately.
15:18 OPTIONS AND ACCESSORIES:
- Auto Shuttle System; electrically operated for extremely smooth cycle, single speed with gentle acceleration and deceleration of shuttle. Interlocked with Banner hand sensors for safe platen operation. Includes side clear panel guards at shuttle bearing side locations.
- Seal Tool Recognition System; RFID electronic sensing feature for accurate program changeovers, requires Process Control System option for pre-programmed menu selections matching the tool ID, no tooling mix-ups ever again. RFID chip on the tooling verifies the use of the correct PLC recipe on every cycle.
- Stainless steel framework, welded 3/16” rectangular tubing far superior to angle iron and sheet metal, includes stainless steel controls cabinet
- Safety interlocking Lexan safety guard covers, hard wired interlocks. Class 3
- Direct Force Sensing System (patented) provides a digital reading of the force (lbs.-force) exerted by the tray sealer press against the tray or blister seal tool area (requires controls option a or b below). Speeds validation experiment settings with new package designs. For reference only, not a closed loop system.
15:18 PROCESS CONTROL & DOCUMENTATION OPTIONS:
a) Auto Pressure Process Control Systemincluding Mitsubishi PLC & E1032 operator interface, pressure transducer using I/P transmitter for automatic programmed fine air pressure closed loop control with PLC controlled auto regulator. Standard AV digital pressure and temperature monitors with alarm system. Enhanced screen. Provides Auto Air Pressure Control settings on the screen in lieu of standard manually set regulator. Stores 99 programs and can utilize optional tooling ID sensor system to prevent mix-ups and operator delay or errors on changeovers (see Tool ID System).
b) Seal Parameter Documentation System with above Process Control System including Mitsubishi PLC & E1032, intelligent operator with USB output of pressure transducer, alarms and cut-off external signals in PCL5. Provides communication channel to PCL5 printer for printing parameter information to labels or report document on every cycle (standard) or to a lot run report (optional). Printer not included (ex. HP Laserjet P2015).
c) Pressure setting through PLC using I/P transmitter (included in a & b above or a la carte option here) instead of standard precision manual regulator.
d) Allen Bradley PLC and PanelView 550 or 600 systems in lieu of Mits E1032
e) Atlas Vac Network System. LAN or PC communication system, requires option a) or b) above plus this upgrade of Mitsubishi Operator interface memory, uploads data to client network server for data storage and report functions. Also enables the downloading of PLC recipe from secure file server. Can be offered with AB PLC components but must utilize Mits Operator Interface (request special quote).
f) Calibration Services, IQ, OQ, other
g) Translations of PLC Screens and Manuals
h) CE rating certification
i) UL listing on controls cabinet
j) Barcode reader & integration
k) Printer; HP Laserjet P2015